更改

跳到导航 跳到搜索
删除1,581字节 、 2022年3月29日 (二) 10:57
无编辑摘要
第7行: 第7行:  
thumb|right|350px|Basic components of Hodgkin–Huxley-type models. Hodgkin–Huxley type models represent the biophysical characteristic of cell membranes. The lipid bilayer is represented as a capacitance (C<SUB>m</SUB>). Voltage-gated and leak ion channels are represented by nonlinear (g<SUB>n</SUB>) and linear (g<SUB>L</SUB>) conductances, respectively. The electrochemical gradients driving the flow of ions are represented by batteries (E), and ion pumps and exchangers are represented by current sources (I<SUB>p</SUB>).
 
thumb|right|350px|Basic components of Hodgkin–Huxley-type models. Hodgkin–Huxley type models represent the biophysical characteristic of cell membranes. The lipid bilayer is represented as a capacitance (C<SUB>m</SUB>). Voltage-gated and leak ion channels are represented by nonlinear (g<SUB>n</SUB>) and linear (g<SUB>L</SUB>) conductances, respectively. The electrochemical gradients driving the flow of ions are represented by batteries (E), and ion pumps and exchangers are represented by current sources (I<SUB>p</SUB>).
   −
拇指 | 右侧 | 350px | Hodgkin-huxley 型模型的基本组件。Hodgkin-Huxley 型模型代表了细胞膜的生物物理特性。脂双分子层表示为电容(c < sub > m </sub >)。电压门控离子通道和泄漏离子通道分别用非线性(g < sub > n </sub >)和线性(g < sub > l </sub >)电导表示。驱动离子流的电化学梯度用电池(e)表示,离子泵和离子交换器用电流源表示(i < sub > p </sub >)。
+
Hodgkin-Huxley 型模型的基本组成部分。Hodgkin-Huxley 型模型代表了细胞膜的生物物理特性。磷脂双分子层表示为一个电容项。电压门控离子通道和漏离子通道分别用非线性和线性电导表示。驱动离子流动的电化学梯度用电池(e)表示,离子泵和离子交换器用电流源表示(i < sub > p )。
    
The '''Hodgkin–Huxley model''', or '''conductance-based model''', is a [[mathematical model]] that describes how [[action potential]]s in [[neuron]]s are initiated and propagated. It is a set of [[nonlinear]] [[differential equation]]s that approximates the electrical characteristics of excitable cells such as neurons and [[cardiac muscle|cardiac myocytes]]. It is a continuous-time [[dynamical system]].
 
The '''Hodgkin–Huxley model''', or '''conductance-based model''', is a [[mathematical model]] that describes how [[action potential]]s in [[neuron]]s are initiated and propagated. It is a set of [[nonlinear]] [[differential equation]]s that approximates the electrical characteristics of excitable cells such as neurons and [[cardiac muscle|cardiac myocytes]]. It is a continuous-time [[dynamical system]].
   −
The Hodgkin–Huxley model, or conductance-based model, is a mathematical model that describes how action potentials in neurons are initiated and propagated. It is a set of nonlinear differential equations that approximates the electrical characteristics of excitable cells such as neurons and cardiac myocytes. It is a continuous-time dynamical system.
+
Hodgkin-Huxley 模型,或者说基于电导的模型,是一个描述神经元中动作电位如何产生和传导的数学模型。它是一组非线性微分方程,用于近似可兴奋细胞(如神经元和心肌细胞)的电学特性。它是一个时间连续的动力系统。
 
  −
Hodgkin-Huxley 模型,或者说基于电导的模型,是一个描述神经元中动作电位如何发生和传播的数学模型。它是一组非线性微分方程,近似于神经元和心肌细胞等可兴奋细胞的电学特性。它是一个连续的时间动力系统。
      
[[Alan Hodgkin]] and [[Andrew Huxley]] described the model in 1952 to explain the ionic mechanisms underlying the initiation and propagation of action potentials in the [[squid giant axon]].<ref name=HH>{{cite journal | vauthors = Hodgkin AL, Huxley AF | title = A quantitative description of membrane current and its application to conduction and excitation in nerve | journal = The Journal of Physiology | volume = 117 | issue = 4 | pages = 500–44 | date = August 1952 | pmid = 12991237 | pmc = 1392413 | doi = 10.1113/jphysiol.1952.sp004764 }}</ref>  They received the 1963 [[Nobel Prize in Physiology or Medicine]] for this work.
 
[[Alan Hodgkin]] and [[Andrew Huxley]] described the model in 1952 to explain the ionic mechanisms underlying the initiation and propagation of action potentials in the [[squid giant axon]].<ref name=HH>{{cite journal | vauthors = Hodgkin AL, Huxley AF | title = A quantitative description of membrane current and its application to conduction and excitation in nerve | journal = The Journal of Physiology | volume = 117 | issue = 4 | pages = 500–44 | date = August 1952 | pmid = 12991237 | pmc = 1392413 | doi = 10.1113/jphysiol.1952.sp004764 }}</ref>  They received the 1963 [[Nobel Prize in Physiology or Medicine]] for this work.
第19行: 第17行:  
Alan Hodgkin and Andrew Huxley described the model in 1952 to explain the ionic mechanisms underlying the initiation and propagation of action potentials in the squid giant axon.  They received the 1963 Nobel Prize in Physiology or Medicine for this work.
 
Alan Hodgkin and Andrew Huxley described the model in 1952 to explain the ionic mechanisms underlying the initiation and propagation of action potentials in the squid giant axon.  They received the 1963 Nobel Prize in Physiology or Medicine for this work.
   −
1952年,Alan Hodgkin 和 Andrew Huxley 描述了这个模型,以解释乌贼巨大神经轴动作电位启动和传播的离子机制。他们因为这项工作获得了1963年的诺贝尔生理学或医学奖。
+
1952年,Alan Hodgkin 和 Andrew Huxley 描述了这个模型,来解释乌贼巨大神经轴突中动作电位的产生和传导的离子机制。他们因为这项工作获得了1963年的诺贝尔生理学或医学奖。
    
==Basic components==
 
==Basic components==
第26行: 第24行:  
The typical Hodgkin–Huxley model treats each component of an excitable cell as an electrical element (as shown in the figure). The lipid bilayer is represented as a capacitance (C<SUB>m</SUB>). Voltage-gated ion channels are represented by electrical conductances (g<SUB>n</SUB>, where n is the specific ion channel) that depend on both voltage and time.  Leak channels are represented by linear conductances (g<SUB>L</SUB>). The electrochemical gradients driving the flow of ions are represented by voltage sources (E<SUB>n</SUB>) whose voltages are determined by the ratio of the intra- and extracellular concentrations of the ionic species of interest. Finally, ion pumps are represented by current sources (I<SUB>p</SUB>). The membrane potential is denoted by V<SUB>m</SUB>.
 
The typical Hodgkin–Huxley model treats each component of an excitable cell as an electrical element (as shown in the figure). The lipid bilayer is represented as a capacitance (C<SUB>m</SUB>). Voltage-gated ion channels are represented by electrical conductances (g<SUB>n</SUB>, where n is the specific ion channel) that depend on both voltage and time.  Leak channels are represented by linear conductances (g<SUB>L</SUB>). The electrochemical gradients driving the flow of ions are represented by voltage sources (E<SUB>n</SUB>) whose voltages are determined by the ratio of the intra- and extracellular concentrations of the ionic species of interest. Finally, ion pumps are represented by current sources (I<SUB>p</SUB>). The membrane potential is denoted by V<SUB>m</SUB>.
   −
= = 基本成分 = = 典型的 Hodgkin-Huxley 模型将可兴奋细胞的每个成分都当作电子元件来处理(如图所示)。脂双分子层表示为电容(c < sub > m </sub >)。电压门控离子通道由电导表示(g < sub > n </sub > ,其中 n 是特定的离子通道) ,它同时依赖于电压和时间。泄漏通道用线性电导表示(g < sub > l </sub >)。驱动离子流的电化学梯度由电压源(e < sub > n </sub >)表示,电压源的电压取决于相关离子种类的细胞内和细胞外浓度的比值。最后,用电流源表示离子泵(i < sub > p </sub >)。膜电位表示 v < sub > m </sub >
+
= = 基本成分 = =  
 +
典型的 Hodgkin-Huxley 模型将可兴奋细胞的每个成分都当作电子元件来处理(如图所示)
 +
磷脂双分子层表示为电容。
 +
电压门控离子通道表示为电导(g < sub > n ,其中 n 是特定的离子通道) ,它同时依赖于电压和时间。漏通道表示为线性电导(g < sub > l )
 +
驱使离子流动的电化学梯度表示为电压源(e < sub > n ),电压源的电压取决于相关离子种类在细胞内和细胞外的浓度的比值。
 +
最后,离子泵表示为电流源(i < sub > p )
 +
膜电位表示 v < sub > m 。
    
Mathematically, the current flowing through the lipid bilayer is written as
 
Mathematically, the current flowing through the lipid bilayer is written as
第32行: 第36行:  
Mathematically, the current flowing through the lipid bilayer is written as
 
Mathematically, the current flowing through the lipid bilayer is written as
   −
数学上,流过脂双分子层的电流被写成
+
数学上,流过磷脂双分子层的电流写为
    
: <math>I_c = C_m\frac{{\mathrm d} V_m}{{\mathrm d} t} </math>
 
: <math>I_c = C_m\frac{{\mathrm d} V_m}{{\mathrm d} t} </math>
第44行: 第48行:  
and the current through a given ion channel is the product
 
and the current through a given ion channel is the product
   −
通过给定离子通道的电流
+
流过给定离子通道的电流为乘积
    
: <math>I_i = {g_i}(V_m - V_i) \;</math>
 
: <math>I_i = {g_i}(V_m - V_i) \;</math>
第58行: 第62行:  
Thus, for a cell with sodium and potassium channels, the total current through the membrane is given by:
 
Thus, for a cell with sodium and potassium channels, the total current through the membrane is given by:
   −
其中 v _ i 是 i-th 离子通道的翻转电位。因此,对于具有钠和钾离子通道的细胞,通过细胞膜的总电流是:
+
其中 v _ i 是 i-th 离子通道的反转电位。
 +
因此,对于具有钠和钾离子通道的细胞,通过细胞膜的总电流为:
    
: <math>I = C_m\frac{{\mathrm d} V_m}{{\mathrm d} t}  + g_K(V_m - V_K) + g_{Na}(V_m - V_{Na}) + g_l(V_m - V_l)</math>  
 
: <math>I = C_m\frac{{\mathrm d} V_m}{{\mathrm d} t}  + g_K(V_m - V_K) + g_{Na}(V_m - V_{Na}) + g_l(V_m - V_l)</math>  
第68行: 第73行:  
where I is the total membrane current per unit area, Cm is the membrane capacitance per unit area, gK and gNa are the potassium and sodium conductances per unit area, respectively, VK  and VNa are the potassium and sodium reversal potentials, respectively, and gl and Vl are the leak conductance per unit area and leak reversal potential, respectively. The time dependent elements of this equation are Vm, gNa, and gK, where the last two conductances depend explicitly on voltage as well.
 
where I is the total membrane current per unit area, Cm is the membrane capacitance per unit area, gK and gNa are the potassium and sodium conductances per unit area, respectively, VK  and VNa are the potassium and sodium reversal potentials, respectively, and gl and Vl are the leak conductance per unit area and leak reversal potential, respectively. The time dependent elements of this equation are Vm, gNa, and gK, where the last two conductances depend explicitly on voltage as well.
   −
: i = c _ m frac { mathrm d } v _ m }{ mathrm d } t } + g _ k (v _ m-v _ k) + g _ Na }(v _ m-v _ Na }) + g _ l (v _ m-v _ v _ l)其中 i 为单位面积的总膜电流,Cm 为单位面积的膜电流,gK 和 gNa 为单位面积的钾和钠电容,VK 和 VNa 分别为钾电容和反转电势,钠电容和 Vl 分别为单位面积的渗漏和翻转电位。这个方程中与时间有关的元素是 Vm、 gNa 和 gK,其中最后两个电导也明确地依赖于电压。
+
: i = c _ m frac { mathrm d } v _ m }{ mathrm d } t } + g _ k (v _ m-v _ k) + g _ Na }(v _ m-v _ Na }) + g _ l (v _ m-v _ v _ l)
 +
其中 i 为单位面积的总膜电流,Cm 为单位面积的膜电容,gK 和 gNa 分别为单位面积的钾和钠的电导,VK 和 VNa 分别为钾和钠的反转电位,gl 和 Vl 分别为单位面积的漏电导和漏反转电位。
 +
这个方程中的时间依赖项为 Vm、 gNa 和 gK,其中最后两个电导项也明确地取决于电压。
    
==Ionic current characterization==
 
==Ionic current characterization==
第74行: 第81行:  
==Ionic current characterization==
 
==Ionic current characterization==
   −
= = 离子电流角色塑造 = =  
+
= 离子电流的描述 =
    
In voltage-gated ion channels, the channel conductance <math>g_l</math> is a function of both time and voltage (<math>g_n(t,V)</math> in the figure), while in leak channels <math>g_l</math> is a constant (<math>g_L</math> in the figure).  The current generated by ion pumps is dependent on the ionic species specific to that pump.  The following sections will describe these formulations in more detail.
 
In voltage-gated ion channels, the channel conductance <math>g_l</math> is a function of both time and voltage (<math>g_n(t,V)</math> in the figure), while in leak channels <math>g_l</math> is a constant (<math>g_L</math> in the figure).  The current generated by ion pumps is dependent on the ionic species specific to that pump.  The following sections will describe these formulations in more detail.
   −
In voltage-gated ion channels, the channel conductance g_l is a function of both time and voltage (g_n(t,V) in the figure), while in leak channels g_l is a constant (g_L in the figure).  The current generated by ion pumps is dependent on the ionic species specific to that pump.  The following sections will describe these formulations in more detail.
     −
在电压门控离子通道中,沟道电导 g _ l 是时间和电压(图中为 g _ n (t,v))的函数,而在泄漏通道中,g _ l 是常数(图中为 g _ l)。离子泵产生的电流取决于离子泵特有的离子种类。以下各节将更详细地描述这些公式。
+
在电压门控离子通道中,通道电导 g _ l 是时间和电压(图中为 g _ n (t,v))的函数,而在漏通道中,g _ l 是常数(图中为 g _ l)
 +
由离子泵产生的电流取决于离子泵特定的离子种类。
 +
以下各节将更详细地描述这些公式。
   −
===Voltage-gated ion channels===
+
===电压门控离子通道===
 
Using a series of [[voltage clamp]] experiments and by varying extracellular sodium and potassium concentrations, Hodgkin and Huxley developed a model in which the properties of an excitable cell are described by a set of four [[ordinary differential equation]]s.<ref name="HH"/> Together with the equation for the total current mentioned above, these are:
 
Using a series of [[voltage clamp]] experiments and by varying extracellular sodium and potassium concentrations, Hodgkin and Huxley developed a model in which the properties of an excitable cell are described by a set of four [[ordinary differential equation]]s.<ref name="HH"/> Together with the equation for the total current mentioned above, these are:
    
Using a series of voltage clamp experiments and by varying extracellular sodium and potassium concentrations, Hodgkin and Huxley developed a model in which the properties of an excitable cell are described by a set of four ordinary differential equations. Together with the equation for the total current mentioned above, these are:
 
Using a series of voltage clamp experiments and by varying extracellular sodium and potassium concentrations, Hodgkin and Huxley developed a model in which the properties of an excitable cell are described by a set of four ordinary differential equations. Together with the equation for the total current mentioned above, these are:
   −
通过一系列的电压钳实验,通过改变细胞外钠离子和钾离子浓度,Hodgkin 和 Huxley 建立了一个由四个常微分方程描述兴奋细胞特性的模型。加上上述总电流的等式,这些是:
+
通过改变细胞外钠离子和钾离子的浓度,进行一系列的电压钳实验,Hodgkin 和 Huxley 建立了一个由四个常微分方程描述可兴奋细胞特性的模型。加上上述总电流的方程,这些方程为:
    
: <math>I = C_m\frac{{\mathrm d} V_m}{{\mathrm d} t}  + \bar{g}_\text{K}n^4(V_m - V_K) + \bar{g}_\text{Na}m^3h(V_m - V_{Na}) + \bar{g}_l(V_m - V_l),</math>
 
: <math>I = C_m\frac{{\mathrm d} V_m}{{\mathrm d} t}  + \bar{g}_\text{K}n^4(V_m - V_K) + \bar{g}_\text{Na}m^3h(V_m - V_{Na}) + \bar{g}_l(V_m - V_l),</math>
第117行: 第125行:  
where I is the current per unit area, and \alpha_i  and \beta_i  are rate constants for the i-th ion channel, which depend on voltage but not time. \bar{g}_n is the maximal value of the conductance. n, m, and h are dimensionless quantities between 0 and 1 that are associated with potassium channel activation, sodium channel activation, and sodium channel inactivation, respectively. For  p = (n, m, h),  \alpha_p  and  \beta_p  take the form
 
where I is the current per unit area, and \alpha_i  and \beta_i  are rate constants for the i-th ion channel, which depend on voltage but not time. \bar{g}_n is the maximal value of the conductance. n, m, and h are dimensionless quantities between 0 and 1 that are associated with potassium channel activation, sodium channel activation, and sodium channel inactivation, respectively. For  p = (n, m, h),  \alpha_p  and  \beta_p  take the form
   −
其中 i 是单位面积的电流,而 alpha _ i 和 beta _ i 是 i-th 离子通道的速率常数,它取决于电压而不是时间。巴{ g } _ n 是电导的最大值。N、 m 和 h 是0和1之间的无量纲量,分别与钾离子通道激活、钠通道激活和钠通道失活有关。对于 p = (n,m,h) ,alpha _ p 和 beta _ p 的形式是
+
其中 i 是单位面积的电流,而 alpha _ i 和 beta _ i 是 i-th 离子通道的速率常数,它取决于电压而非时间。
 +
bar{ g } _ n 是电导的最大值。
 +
N、 m 和 h 是0和1之间的无量纲量,分别与钾通道激活、钠通道激活和钠通道失活有关。
 +
对于 p = (n,m,h) ,alpha _ p 和 beta _ p 的形式是
    
: <math>\alpha_p(V_m) = p_\infty(V_m)/\tau_p</math>
 
: <math>\alpha_p(V_m) = p_\infty(V_m)/\tau_p</math>
第145行: 第156行:  
where  V = V_{rest} - V_m  denotes the negative depolarization in mV.
 
where  V = V_{rest} - V_m  denotes the negative depolarization in mV.
   −
P _ infty 和(1-p _ infty)分别是活化和失活的稳态值,通常用 Boltzmann 方程表示为 v _ m 的函数。在 Hodgkin 和 Huxley 的原始论文中,给出了函数 alpha beta: begin { array }{ lll } alpha _ n (v _ m) = frac {0.01(10-V)}{ exp big (frac {10-V }{10} big)-1} & alpha _ m (v _ m) = frac {0.1(25-V)}{ exp big (frac {25-V }{10} big)-1} & alpha _ h (v _ m) = 0.07 expBigg (- frac { v } bigg) beta _ n (v _ m) = 0.125 exp bigg (- frac { v } bigg) & beta _ m (v _ m) = 4 exp bigg (- frac { v }{18} bigg) & beta _ h ()V _ m) = frac {1}{ exp big (frac {30-V }{10} big) + 1} end { array }其中 v = v _ { rest }{ rest }-v _ m 表示 mV 中的负去极化。
+
P _ infty 和(1-p _ infty)分别是激活和失活的稳态值,通常用 Boltzmann 方程表示为 v _ m 的函数。
 +
Hodgkin 和 Huxley 的原始论文中,alpha beta函数如下给出
 +
begin { array }{ lll } alpha _ n (v _ m) = frac {0.01(10-V)}{ exp big (frac {10-V }{10} big)-1} & alpha _ m (v _ m) = frac {0.1(25-V)}{ exp big (frac {25-V }{10} big)-1} & alpha _ h (v _ m) = 0.07 expBigg (- frac { v } bigg) beta _ n (v _ m) = 0.125 exp bigg (- frac { v } bigg) & beta _ m (v _ m) = 4 exp bigg (- frac { v }{18} bigg) & beta _ h ()V _ m) = frac {1}{ exp big (frac {30-V }{10} big) + 1} end { array }
 +
其中...表示mV 中的负去极化(???)
    
While in many current software programs,<ref>Nelson ME (2005) [http://nelson.beckman.illinois.edu/courses/physl317/part1/Lec3_HHsection.pdf Electrophysiological Models In: Databasing the Brain: From Data to Knowledge.] (S. Koslow and S. Subramaniam, eds.) Wiley, New York, pp. 285–301</ref>
 
While in many current software programs,<ref>Nelson ME (2005) [http://nelson.beckman.illinois.edu/courses/physl317/part1/Lec3_HHsection.pdf Electrophysiological Models In: Databasing the Brain: From Data to Knowledge.] (S. Koslow and S. Subramaniam, eds.) Wiley, New York, pp. 285–301</ref>
第165行: 第179行:  
In order to characterize voltage-gated channels, the equations are fit to voltage clamp data. For a derivation of the Hodgkin–Huxley equations under voltage-clamp, see. Briefly, when the membrane potential is held at a constant value (i.e., voltage-clamp), for each value of the membrane potential the nonlinear gating equations reduce to equations of the form:
 
In order to characterize voltage-gated channels, the equations are fit to voltage clamp data. For a derivation of the Hodgkin–Huxley equations under voltage-clamp, see. Briefly, when the membrane potential is held at a constant value (i.e., voltage-clamp), for each value of the membrane potential the nonlinear gating equations reduce to equations of the form:
   −
为了表征电压门控通道,该方程适合于电压钳位数据。关于电压箝位下 Hodgkin-Huxley 方程的推导,请参阅。简单地说,当膜电位保持在一个恒定的值(例如,电压钳)时,对于每个膜电位的值,非线性门控方程可以归结为以下形式的方程:
+
为了表征电压门控通道,该方程适合于电压钳位数据。关于电压箝下 Hodgkin-Huxley 方程的推导,请参阅。
 +
简单地说,当膜电位保持为一个恒定值(例如,电压钳)时,对于膜电位的每个值,非线性门控方程可以归结为以下形式的方程:
    
: <math>m(t) = m_{0} - [ (m_{0}-m_{\infty})(1 - e^{-t/\tau_m})]\, </math>
 
: <math>m(t) = m_{0} - [ (m_{0}-m_{\infty})(1 - e^{-t/\tau_m})]\, </math>
第189行: 第204行:  
Thus, for every value of membrane potential V_{m} the sodium and potassium currents can be described by
 
Thus, for every value of membrane potential V_{m} the sodium and potassium currents can be described by
   −
因此,对于每一个膜电位 v { m }的值,钠电流和钾电流可以用以下方法来描述
+
因此,对于膜电位的每个值 v { m },钠电流和钾电流可以如下描述
    
: <math>I_\mathrm{Na}(t)=\bar{g}_\mathrm{Na} m(V_m)^3h(V_m)(V_m-E_\mathrm{Na}),</math>
 
: <math>I_\mathrm{Na}(t)=\bar{g}_\mathrm{Na} m(V_m)^3h(V_m)(V_m-E_\mathrm{Na}),</math>
第207行: 第222行:  
In order to arrive at the complete solution for a propagated action potential, one must write the current term I on the left-hand side of the first differential equation in terms of V, so that the equation becomes an equation for voltage alone. The relation between I and V can be derived from cable theory and is given by
 
In order to arrive at the complete solution for a propagated action potential, one must write the current term I on the left-hand side of the first differential equation in terms of V, so that the equation becomes an equation for voltage alone. The relation between I and V can be derived from cable theory and is given by
   −
为了得到传播的动作电位的完整解,必须在第一个微分方程的左侧写上电流项 i,使方程成为单独的电压方程。I 和 v 之间的关系可以从电缆理论中推导出来,并给出了
+
为了得到传导的动作电位的完整解,必须在第一个微分方程的左侧写上电流项 i(???),使方程成为单独的电压方程。
 +
I 和 v 之间的关系可以从电缆理论中推导出来,并给出了
    
: <math>I = \frac{a}{2R}\frac{\partial^2V}{\partial x^2}, </math>
 
: <math>I = \frac{a}{2R}\frac{\partial^2V}{\partial x^2}, </math>
第219行: 第235行:  
where a is the radius of the axon, R is the specific resistance of the axoplasm, and x is the position along the nerve fiber. Substitution of this expression for I transforms the original set of equations into a set of partial differential equations, because the voltage becomes a function of both x and t.
 
where a is the radius of the axon, R is the specific resistance of the axoplasm, and x is the position along the nerve fiber. Substitution of this expression for I transforms the original set of equations into a set of partial differential equations, because the voltage becomes a function of both x and t.
   −
其中 a 是轴突的半径,r 是轴浆的比阻力,x 是沿着神经纤维的位置。用这个表达式代替 i,将原来的方程组变换为一组偏微分方程,因为电压变成了 x 和 t 的函数。
+
其中 a 是轴突的半径,r 是轴浆的比阻力(???),x 是沿着神经纤维的位置。
 +
用这个表达式代替 i,将原来的方程组转变为一组偏微分方程,因为电压变成了 x 和 t 的函数。
    
The [[Levenberg–Marquardt algorithm]] is often used to fit these equations to voltage-clamp data.<ref>{{cite book |title=New Ecoinformatics Tools in Environmental Science : Applications and Decision-making |first1=Vladimir F. |last1=Krapivin |first2=Costas A. |last2=Varotsos |first3=Vladimir Yu. |last3=Soldatov |year=2015 |pages=37–38 |publisher=Springer |isbn=9783319139784 |url=https://www.google.com/books/edition/New_Ecoinformatics_Tools_in_Environmenta/bWpnBgAAQBAJ?hl=en&gbpv=1&pg=PA37 }}</ref>
 
The [[Levenberg–Marquardt algorithm]] is often used to fit these equations to voltage-clamp data.<ref>{{cite book |title=New Ecoinformatics Tools in Environmental Science : Applications and Decision-making |first1=Vladimir F. |last1=Krapivin |first2=Costas A. |last2=Varotsos |first3=Vladimir Yu. |last3=Soldatov |year=2015 |pages=37–38 |publisher=Springer |isbn=9783319139784 |url=https://www.google.com/books/edition/New_Ecoinformatics_Tools_in_Environmenta/bWpnBgAAQBAJ?hl=en&gbpv=1&pg=PA37 }}</ref>
第225行: 第242行:  
The Levenberg–Marquardt algorithm is often used to fit these equations to voltage-clamp data.
 
The Levenberg–Marquardt algorithm is often used to fit these equations to voltage-clamp data.
   −
通常采用 Levenberg-Marquardt 算法对电压钳位数据进行拟合。
+
通常采用 Levenberg-Marquardt 算法为这些方程对电压钳数据进行拟合。
    
While the original experiments treated only sodium and potassium channels, the Hodgkin–Huxley model can also be extended to account for other species of [[ion channel]]s.
 
While the original experiments treated only sodium and potassium channels, the Hodgkin–Huxley model can also be extended to account for other species of [[ion channel]]s.
第231行: 第248行:  
While the original experiments treated only sodium and potassium channels, the Hodgkin–Huxley model can also be extended to account for other species of ion channels.
 
While the original experiments treated only sodium and potassium channels, the Hodgkin–Huxley model can also be extended to account for other species of ion channels.
   −
虽然最初的实验只处理钠和钾离子通道,Hodgkin-Huxley 模型也可以扩展到其他种类的离子通道。
+
虽然最初的实验只处理钠和钾通道,Hodgkin-Huxley 模型也可以扩展到其他种类的离子通道。
   −
===Leak channels===
+
===漏通道===
 
Leak channels account for the natural permeability of the membrane to ions and take the form of the equation for voltage-gated channels, where the conductance <math>g_{leak}</math> is a constant. Thus, the leak current due to passive leak ion channels in the Hodgkin-Huxley formalism is <math>I_l=g_{leak}(V-V_{leak})</math>.
 
Leak channels account for the natural permeability of the membrane to ions and take the form of the equation for voltage-gated channels, where the conductance <math>g_{leak}</math> is a constant. Thus, the leak current due to passive leak ion channels in the Hodgkin-Huxley formalism is <math>I_l=g_{leak}(V-V_{leak})</math>.
    
Leak channels account for the natural permeability of the membrane to ions and take the form of the equation for voltage-gated channels, where the conductance g_{leak} is a constant. Thus, the leak current due to passive leak ion channels in the Hodgkin-Huxley formalism is I_l=g_{leak}(V-V_{leak}).
 
Leak channels account for the natural permeability of the membrane to ions and take the form of the equation for voltage-gated channels, where the conductance g_{leak} is a constant. Thus, the leak current due to passive leak ion channels in the Hodgkin-Huxley formalism is I_l=g_{leak}(V-V_{leak}).
   −
= = = 泄漏通道 = = = 泄漏通道解释了膜对离子的天然渗透性,其形式为电压门控通道方程,其中 g {泄漏}为常数。因此,在 Hodgkin-Huxley 公式中,被动泄漏离子通道引起的泄漏电流为 i _ l = g _ { leak }(V-V _ { leak })。
+
漏通道解释了膜对离子的天然渗透性,其形式为电压门控通道方程,其中电导g {}为常数。
 
+
因此,在 Hodgkin-Huxley 公式中,被动漏离子通道引起的漏电流为 i _ l = g _ { leak }(V-V _ { leak })。
===Pumps and exchangers===
+
===泵和交换器===
 
The membrane potential depends upon the maintenance of ionic concentration gradients across it. The maintenance of these concentration gradients requires active transport of ionic species. The sodium-potassium and sodium-calcium exchangers are the best known of these.  Some of the basic properties of the Na/Ca exchanger have already been well-established: the stoichiometry of exchange is 3 Na<SUP>+</SUP>: 1 Ca<SUP>2+</SUP> and the exchanger is electrogenic and voltage-sensitive. The Na/K exchanger has also been described in detail, with a 3 Na<SUP>+</SUP>: 2 K<SUP>+</SUP> stoichiometry.<ref name="Rakowski_1989">{{cite journal | vauthors = Rakowski RF, Gadsby DC, De Weer P | title = Stoichiometry and voltage dependence of the sodium pump in voltage-clamped, internally dialyzed squid giant axon | journal = The Journal of General Physiology | volume = 93 | issue = 5 | pages = 903–41 | date = May 1989 | pmid = 2544655 | doi = 10.1085/jgp.93.5.903 | pmc=2216238}}</ref><ref name=Hille>{{cite book|last=Hille|first=Bertil | name-list-style = vanc | title=Ion channels of excitable membranes|year=2001|publisher=Sinauer|location=Sunderland, Massachusetts|isbn=978-0-87893-321-1 | edition = 3rd }}</ref>
 
The membrane potential depends upon the maintenance of ionic concentration gradients across it. The maintenance of these concentration gradients requires active transport of ionic species. The sodium-potassium and sodium-calcium exchangers are the best known of these.  Some of the basic properties of the Na/Ca exchanger have already been well-established: the stoichiometry of exchange is 3 Na<SUP>+</SUP>: 1 Ca<SUP>2+</SUP> and the exchanger is electrogenic and voltage-sensitive. The Na/K exchanger has also been described in detail, with a 3 Na<SUP>+</SUP>: 2 K<SUP>+</SUP> stoichiometry.<ref name="Rakowski_1989">{{cite journal | vauthors = Rakowski RF, Gadsby DC, De Weer P | title = Stoichiometry and voltage dependence of the sodium pump in voltage-clamped, internally dialyzed squid giant axon | journal = The Journal of General Physiology | volume = 93 | issue = 5 | pages = 903–41 | date = May 1989 | pmid = 2544655 | doi = 10.1085/jgp.93.5.903 | pmc=2216238}}</ref><ref name=Hille>{{cite book|last=Hille|first=Bertil | name-list-style = vanc | title=Ion channels of excitable membranes|year=2001|publisher=Sinauer|location=Sunderland, Massachusetts|isbn=978-0-87893-321-1 | edition = 3rd }}</ref>
    
The membrane potential depends upon the maintenance of ionic concentration gradients across it. The maintenance of these concentration gradients requires active transport of ionic species. The sodium-potassium and sodium-calcium exchangers are the best known of these.  Some of the basic properties of the Na/Ca exchanger have already been well-established: the stoichiometry of exchange is 3 Na<SUP>+</SUP>: 1 Ca<SUP>2+</SUP> and the exchanger is electrogenic and voltage-sensitive. The Na/K exchanger has also been described in detail, with a 3 Na<SUP>+</SUP>: 2 K<SUP>+</SUP> stoichiometry.
 
The membrane potential depends upon the maintenance of ionic concentration gradients across it. The maintenance of these concentration gradients requires active transport of ionic species. The sodium-potassium and sodium-calcium exchangers are the best known of these.  Some of the basic properties of the Na/Ca exchanger have already been well-established: the stoichiometry of exchange is 3 Na<SUP>+</SUP>: 1 Ca<SUP>2+</SUP> and the exchanger is electrogenic and voltage-sensitive. The Na/K exchanger has also been described in detail, with a 3 Na<SUP>+</SUP>: 2 K<SUP>+</SUP> stoichiometry.
   −
= = = 泵和交换器 = = = 膜电位取决于维持其上的离子浓度梯度。维持这些浓度梯度需要离子种类的主动运输。其中钠钾交换器和钠钙交换器最为著名。钠钙交换器的一些基本性质已经得到确认: 交换的化学计量比为3 Na < sup > + </sup > : 1 Ca < sup > 2 + </sup > ,交换器具有产电性和电压敏感性。本文还详细描述了 Na/k 交换剂,用3个 Na < sup > + </sup > : 2 k < sup > + </sup > 化学计量学方法。
+
膜电位取决于其上的离子浓度梯度的保持。
 +
维持这些浓度梯度需要这几种离子的主动运输。
 +
其中钠钾交换器和钠钙交换器最为著名。
 +
钠钙交换器的一些基本性质已经得到公认: 交换的化学计量比为3 Na < sup > + : 1 Ca < sup > 2 + ,交换器具有产电性和电压敏感性。
 +
文献中还详细描述了 Na/k 交换器,用3个 Na < sup > + : 2 k < sup > + 的化学计量。
   −
==Mathematical properties==
+
==数学性质==
 
The Hodgkin–Huxley model can be thought of as a [[differential equation]] system with four [[state variable]]s, <math>V_m(t), n(t), m(t)</math>, and <math>h(t)</math>, that change with respect to time <math>t</math>. The system is difficult to study because it is a [[nonlinear|nonlinear system]] and cannot be solved analytically. However, there are many numerical methods available to analyze the system. Certain properties and general behaviors, such as [[limit cycle]]s, can be proven to exist.
 
The Hodgkin–Huxley model can be thought of as a [[differential equation]] system with four [[state variable]]s, <math>V_m(t), n(t), m(t)</math>, and <math>h(t)</math>, that change with respect to time <math>t</math>. The system is difficult to study because it is a [[nonlinear|nonlinear system]] and cannot be solved analytically. However, there are many numerical methods available to analyze the system. Certain properties and general behaviors, such as [[limit cycle]]s, can be proven to exist.
    
The Hodgkin–Huxley model can be thought of as a differential equation system with four state variables, V_m(t), n(t), m(t), and h(t), that change with respect to time t. The system is difficult to study because it is a nonlinear system and cannot be solved analytically. However, there are many numerical methods available to analyze the system. Certain properties and general behaviors, such as limit cycles, can be proven to exist.
 
The Hodgkin–Huxley model can be thought of as a differential equation system with four state variables, V_m(t), n(t), m(t), and h(t), that change with respect to time t. The system is difficult to study because it is a nonlinear system and cannot be solved analytically. However, there are many numerical methods available to analyze the system. Certain properties and general behaviors, such as limit cycles, can be proven to exist.
   −
= = = 数学性质 = = Hodgkin-Huxley 模型可以被认为是一个具有4个状态变量 v _ m (t) ,n (t) ,m (t)和 h (t)的微分方程系统,它们随着时间 t 的变化而变化。这个系统很难研究,因为它是一个非线性,无法用解析方法求解。然而,有许多数值方法可用于分析该系统。某些性质和一般行为,如极限环,可以被证明是存在的。
+
可以认为Hodgkin-Huxley 模型是一个具有4个状态变量 v _ m (t) ,n (t) ,m (t)和 h (t)的微分方程系统,它们随着时间 t 变化。
 +
这个系统很难研究,因为它是一个非线性系统,无法用解析法求解。
 +
然而,有许多数值方法可用于分析该系统。可以证明某些性质和一般行为(如极限环)是存在的。
    
[[File:Hodgkin Huxley Limit Cycle.png|thumb|left|A simulation of the Hodgkin–Huxley model in phase space, in terms of voltage v(t) and potassium gating variable n(t). The closed curve is known as a [[limit cycle]].]]
 
[[File:Hodgkin Huxley Limit Cycle.png|thumb|left|A simulation of the Hodgkin–Huxley model in phase space, in terms of voltage v(t) and potassium gating variable n(t). The closed curve is known as a [[limit cycle]].]]
第266行: 第289行:  
Because there are four state variables, visualizing the path in phase space can be difficult. Usually two variables are chosen, voltage V_m(t) and the potassium gating variable n(t), allowing one to visualize the limit cycle. However, one must be careful because this is an ad-hoc method of visualizing the 4-dimensional system. This does not prove the existence of the limit cycle.
 
Because there are four state variables, visualizing the path in phase space can be difficult. Usually two variables are chosen, voltage V_m(t) and the potassium gating variable n(t), allowing one to visualize the limit cycle. However, one must be careful because this is an ad-hoc method of visualizing the 4-dimensional system. This does not prove the existence of the limit cycle.
   −
由于有四个状态变量,在相空间中路径的可视化可能是困难的。通常选择两个变量,电压 v _ m (t)和钾浇注变量 n (t) ,使人可以想象极限环。但是,一定要小心,因为这是一个四维系统可视化的特别方法。这并不能证明极限环的存在性。
+
由于有四个状态变量,想象相空间中的路径会比较困难。
 +
通常选择两个变量,电压 v _ m (t)和钾门控变量 n (t) ,这样就能想象出极限环。
 +
但是,要注意这只是一个想象四维系统的特殊方法,并不能证明极限环的存在性。
    
A better [[projection (mathematics)|projection]] can be constructed from a careful analysis of the [[Jacobian matrix and determinant|Jacobian]] of the system, evaluated at the [[equilibrium point]]. Specifically, the [[eigenvalues]] of the Jacobian are indicative of the [[center manifold]]'s existence. Likewise, the [[Eigenvalues and eigenvectors|eigenvectors]] of the Jacobian reveal the center manifold's [[Orientation (geometry)|orientation]]. The Hodgkin–Huxley model has two negative eigenvalues and two complex eigenvalues with slightly positive real parts. The eigenvectors associated with the two negative eigenvalues will reduce to zero as time ''t'' increases. The remaining two complex eigenvectors define the center manifold.  In other words, the 4-dimensional system collapses onto a 2-dimensional plane.  Any solution starting off the center manifold will decay towards the center manifold. Furthermore, the limit cycle is contained on the center manifold.
 
A better [[projection (mathematics)|projection]] can be constructed from a careful analysis of the [[Jacobian matrix and determinant|Jacobian]] of the system, evaluated at the [[equilibrium point]]. Specifically, the [[eigenvalues]] of the Jacobian are indicative of the [[center manifold]]'s existence. Likewise, the [[Eigenvalues and eigenvectors|eigenvectors]] of the Jacobian reveal the center manifold's [[Orientation (geometry)|orientation]]. The Hodgkin–Huxley model has two negative eigenvalues and two complex eigenvalues with slightly positive real parts. The eigenvectors associated with the two negative eigenvalues will reduce to zero as time ''t'' increases. The remaining two complex eigenvectors define the center manifold.  In other words, the 4-dimensional system collapses onto a 2-dimensional plane.  Any solution starting off the center manifold will decay towards the center manifold. Furthermore, the limit cycle is contained on the center manifold.
   −
A better projection can be constructed from a careful analysis of the Jacobian of the system, evaluated at the equilibrium point. Specifically, the eigenvalues of the Jacobian are indicative of the center manifold's existence. Likewise, the eigenvectors of the Jacobian reveal the center manifold's orientation. The Hodgkin–Huxley model has two negative eigenvalues and two complex eigenvalues with slightly positive real parts. The eigenvectors associated with the two negative eigenvalues will reduce to zero as time t increases. The remaining two complex eigenvectors define the center manifold.  In other words, the 4-dimensional system collapses onto a 2-dimensional plane.  Any solution starting off the center manifold will decay towards the center manifold. Furthermore, the limit cycle is contained on the center manifold.
+
在系统的平衡点处对雅可比矩阵仔细分析,可以构造出一个更好的投影。
 
+
具体来说,雅可比矩阵的特征值指示中心流形的存在。
通过对系统的雅可比矩阵的仔细分析,可以构造出一个更好的投影,该投影在平衡点进行了评估。具体来说,特征值的雅可比是指示中心流形的存在。同样,雅可比的特征向量揭示了中心流形的方向。Hodgkin-Huxley 模型有两个负的特征值和两个带有轻微正实部的复特征值。随着时间 t 的增加,与两个负特征值相关的特征向量将减少到零。剩下的两个复特征向量定义了中心流形。换句话说,这个四维系统坍缩到一个二维平面上。任何解决方案开始的中心歧管将衰减到中心歧管。此外,极限环包含在中心流形上。
+
同样,雅可比的特征向量揭示了中心流形的方向。
 +
Hodgkin-Huxley 模型有两个负的特征值和两个具有轻微取正的实部的复特征值。
 +
随着时间 t 的增加,与两个负特征值相关的特征向量将减少到零。
 +
剩下的两个复特征向量定义了中心流形。换句话说,这个四维系统会坍缩到一个二维平面上。
 +
任何开始于中心流形的解将衰减至中心流形。(???)
 +
此外,极限环包含在中心流形上。
    
[[File:Hodgkins Huxley Plot.gif|thumb|right|360px|The voltage ''v''(''t'') (in millivolts) of the Hodgkin–Huxley model, graphed over 50 milliseconds. The injected current varies from −5 nanoamps to 12 nanoamps. The graph passes through three stages: an equilibrium stage, a single-spike stage, and a limit cycle stage.]]
 
[[File:Hodgkins Huxley Plot.gif|thumb|right|360px|The voltage ''v''(''t'') (in millivolts) of the Hodgkin–Huxley model, graphed over 50 milliseconds. The injected current varies from −5 nanoamps to 12 nanoamps. The graph passes through three stages: an equilibrium stage, a single-spike stage, and a limit cycle stage.]]
   −
thumb|right|360px|The voltage v(t) (in millivolts) of the Hodgkin–Huxley model, graphed over 50 milliseconds. The injected current varies from −5 nanoamps to 12 nanoamps. The graph passes through three stages: an equilibrium stage, a single-spike stage, and a limit cycle stage.
+
模型的电压 v (t)(毫伏) ,图中超过50毫秒。注入电流从 -5纳安到12纳安不等。该图经历了三个阶段: 平衡阶段、单峰阶段和极限环阶段。(???)
 
  −
拇指 | 右 | 360px | Hodgkin-Huxley 模型的电压 v (t)(毫伏) ,用图表表示超过50毫秒。注入电流从 -5纳安到12纳安不等。该图经历了三个阶段: 平衡阶段、单穗阶段和极限环阶段。
     −
===Bifurcations===
+
===分岔===
 
If the injected current <math>I</math> were used as a [[bifurcation theory|bifurcation parameter]], then the Hodgkin–Huxley model undergoes a [[Hopf bifurcation]]. As with most neuronal models, increasing the injected current will increase the firing rate of the neuron. One consequence of the Hopf bifurcation is that there is a minimum firing rate. This means that either the neuron is not firing at all (corresponding to zero frequency), or firing at the minimum firing rate. Because of the [[all-or-none law|all-or-none principle]], there is no smooth increase in [[action potential]] amplitude, but rather there is a sudden "jump" in amplitude. The resulting transition is known as a [http://www.scholarpedia.org/article/Canards canard].
 
If the injected current <math>I</math> were used as a [[bifurcation theory|bifurcation parameter]], then the Hodgkin–Huxley model undergoes a [[Hopf bifurcation]]. As with most neuronal models, increasing the injected current will increase the firing rate of the neuron. One consequence of the Hopf bifurcation is that there is a minimum firing rate. This means that either the neuron is not firing at all (corresponding to zero frequency), or firing at the minimum firing rate. Because of the [[all-or-none law|all-or-none principle]], there is no smooth increase in [[action potential]] amplitude, but rather there is a sudden "jump" in amplitude. The resulting transition is known as a [http://www.scholarpedia.org/article/Canards canard].
   第286行: 第314行:     
如果将注入电流 i 作为分岔参数,那么 Hodgkin-Huxley 模型将经历一个霍普夫分岔。和大多数神经元模型一样,增加注入电流会增加神经元的放电频率。霍普夫分岔的一个结果就是有一个最低的开火率。这意味着要么神经元根本没有放电(对应于零频率) ,要么以最低放电速率放电。由于“全有或全无”原理,动作电位振幅的增加不是平稳的,而是突然的“跳跃”。由此产生的转变被称为谣言。
 
如果将注入电流 i 作为分岔参数,那么 Hodgkin-Huxley 模型将经历一个霍普夫分岔。和大多数神经元模型一样,增加注入电流会增加神经元的放电频率。霍普夫分岔的一个结果就是有一个最低的开火率。这意味着要么神经元根本没有放电(对应于零频率) ,要么以最低放电速率放电。由于“全有或全无”原理,动作电位振幅的增加不是平稳的,而是突然的“跳跃”。由此产生的转变被称为谣言。
 +
如果将注入电流 i 作为分岔参数,那么 Hodgkin-Huxley 模型将经历一个霍普夫分岔。
 +
和大多数神经元模型一样,增加注入电流会增加神经元的发放率。
 +
霍普夫分岔的一个结果就是存在一个最低的发放率。
 +
这意味着要么神经元根本没有发放(对应于零频率) ,要么以最低发放率发放。
 +
由于“全或无”原理,动作电位的幅度不存在平稳的增加,而是幅度上的突然“跳跃”。
 +
由此产生的转变被称为鸭解。
    
==Improvements and alternative models==
 
==Improvements and alternative models==
第304行: 第338行:  
*The Poisson–Nernst–Planck (PNP) model is based on a mean-field approximation of ion interactions and continuum descriptions of concentration and electrostatic potential.
 
*The Poisson–Nernst–Planck (PNP) model is based on a mean-field approximation of ion interactions and continuum descriptions of concentration and electrostatic potential.
   −
霍奇金-赫胥黎模型被认为是20世纪生物物理学的伟大成就之一。尽管如此,现代 Hodgkin-huxley 型模型已经在几个重要方面得到了扩展:  
+
霍奇金-赫胥黎模型被认为是20世纪生物物理学的伟大成就之一。尽管如此,现代 Hodgkin-huxley 型模型已经在几个重要方面得到了扩展:
* 根据实验数据加入了额外的离子通道群。
+
* 根据实验数据引入了额外的离子通道群。
* Hodgkin-Huxley 模型经过修正,纳入了过渡态理论,并产生了热力学 Hodgkin-Huxley 模型。
+
* 对Hodgkin-Huxley 模型加以修正,加入了过渡态理论,并产生了热力学 Hodgkin-Huxley 模型。
* 模型通常包含高度复杂的树突和轴突几何形状,通常基于显微镜数据。
+
* 通常基于显微镜数据,模型通常包含树突和轴突的高度复杂的几何形状。
 
* 离子通道行为的随机模型,导致随机混合系统。
 
* 离子通道行为的随机模型,导致随机混合系统。
* Poisson-Nernst-Planck 模型是基于离子相互作用的平均场近似以及浓度和静电势的连续描述。
+
* Poisson-Nernst-Planck 模型是基于离子相互作用的平均场近似以及浓度和静电势的连续描述建立的。
    
Several simplified neuronal models have also been developed (such as the [[FitzHugh–Nagumo model]]), facilitating efficient large-scale simulation of groups of neurons, as well as mathematical insight into dynamics of action potential generation.
 
Several simplified neuronal models have also been developed (such as the [[FitzHugh–Nagumo model]]), facilitating efficient large-scale simulation of groups of neurons, as well as mathematical insight into dynamics of action potential generation.
第315行: 第349行:  
Several simplified neuronal models have also been developed (such as the FitzHugh–Nagumo model), facilitating efficient large-scale simulation of groups of neurons, as well as mathematical insight into dynamics of action potential generation.
 
Several simplified neuronal models have also been developed (such as the FitzHugh–Nagumo model), facilitating efficient large-scale simulation of groups of neurons, as well as mathematical insight into dynamics of action potential generation.
   −
一些简化的神经元模型(如 FitzHugh-Nagumo 模型)也已经被开发出来,它们有助于对神经元群进行有效的大规模模拟,以及对动作电位产生动力学的数学洞察。
+
一些简化的神经元模型(如 FitzHugh-Nagumo 模型)也发展了出来,它们有助于对神经元群进行高效的大规模模拟,以及对动作电位产生的动力学的数学洞察。
    
==See also==
 
==See also==
第352行: 第386行:       −
动作电位  
+
* 动作电位  
 
* 阳极破坏激发  
 
* 阳极破坏激发  
 
* 自波  
 
* 自波  
第360行: 第394行:  
* Galves-Löcherbach 模型  
 
* Galves-Löcherbach 模型  
 
* GHK 通量方程  
 
* GHK 通量方程  
* 戈德曼方程
+
* Goldman 方程
* 记忆电阻
+
* 忆阻器
 
* 反应扩散  
 
* 反应扩散  
 
* Theta 模型  
 
* Theta 模型  
82

个编辑

导航菜单